![]() The command timeout within the SourceActivity subsystem.įor systems with large numbers of sources the Source Activity Monitor may have difficulty updating state information before the database command times out. SourceActivityService SourceActivity.CommandTimeout It is important to take into account that decreasing this value might lead to timeout in other procedures. If the Reports tab in the Data Quality plugin of the Admin Tool is throwing a timeout message, this value can be increased to allow more processing to take place. The command timeout within the StorageAccess subsystem. WebServices Sto rageAccess.CommandTimeout This value can be changed to reduce the occurrence of this timeout.įor large ION EEM systems (those with over 10,000 Source/Measurement Pairs) where the Power Quality module is of great importance, the DataAccessBase.CommandTimeout setting should be increased because the PQ event queries are complex and may timeout when querying over a large time span (ie, several months). It can take a long time for the page to load. When you have a large number (>500) of Reports, Trend Analysis, PQ Analysis, or Weblinks and Files. ![]() A value of 0 indicates no limit, and should be avoided in a CommandTimeout because an attempt to execute a command will wait indefinitely. Gets or sets the wait time before terminating the attempt to execute a SQL command and generating an error.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |